Struct glium::draw_parameters::Stencil  
                   
                       [−]
                   
               [src]
pub struct Stencil {
    pub test_clockwise: StencilTest,
    pub reference_value_clockwise: i32,
    pub write_mask_clockwise: u32,
    pub fail_operation_clockwise: StencilOperation,
    pub pass_depth_fail_operation_clockwise: StencilOperation,
    pub depth_pass_operation_clockwise: StencilOperation,
    pub test_counter_clockwise: StencilTest,
    pub reference_value_counter_clockwise: i32,
    pub write_mask_counter_clockwise: u32,
    pub fail_operation_counter_clockwise: StencilOperation,
    pub pass_depth_fail_operation_counter_clockwise: StencilOperation,
    pub depth_pass_operation_counter_clockwise: StencilOperation,
}Describes the parameters that must be used for the stencil operations when drawing.
Fields
test_clockwise: StencilTest
                           A comparison against the existing value in the stencil buffer.
Only relevant for faces that are clockwise on the target surface. Other faces, points and
lines use stencil_test_counter_clockwise instead.
The default value is AlwaysPass.
reference_value_clockwise: i32
                           Reference value that is used by stencil_test_clockwise, stencil_fail_operation_clockwise,
stencil_pass_depth_fail_operation_clockwise and stencil_depth_pass_operation_clockwise.
write_mask_clockwise: u32
                           Allows specifying a mask when writing data on the stencil buffer.
Only relevant for faces that are clockwise on the target surface. Other faces, points and
lines use stencil_write_mask_counter_clockwise instead.
The default value is 0xffffffff.
fail_operation_clockwise: StencilOperation
                           Specifies the operation to do when a fragment fails the stencil test.
The stencil test is the test specified by stencil_test_clockwise.
Only relevant for faces that are clockwise on the target surface. Other faces, points and
lines use stencil_fail_operation_counter_clockwise instead.
The default value is Keep.
pass_depth_fail_operation_clockwise: StencilOperation
                           Specifies the operation to do when a fragment passes the stencil test but fails the depth test.
The stencil test is the test specified by stencil_test_clockwise.
Only relevant for faces that are clockwise on the target surface. Other faces, points and
lines use stencil_pass_depth_fail_operation_counter_clockwise instead.
The default value is Keep.
depth_pass_operation_clockwise: StencilOperation
                           Specifies the operation to do when a fragment passes both the stencil and depth tests.
The stencil test is the test specified by stencil_test_clockwise.
Only relevant for faces that are clockwise on the target surface. Other faces, points and
lines use stencil_depth_pass_operation_counter_clockwise instead.
The default value is Keep.
test_counter_clockwise: StencilTest
                           A comparaison against the existing value in the stencil buffer.
Only relevant for points, lines and faces that are counter-clockwise on the target surface.
Other faces use stencil_test_counter_clockwise instead.
The default value is AlwaysPass.
reference_value_counter_clockwise: i32
                           Reference value that is used by stencil_test_counter_clockwise,
stencil_fail_operation_counter_clockwise,
stencil_pass_depth_fail_operation_counter_clockwise and
stencil_depth_pass_operation_counter_clockwise.
write_mask_counter_clockwise: u32
                           Allows specifying a mask when writing data on the stencil buffer.
Only relevant for points, lines and faces that are counter-clockwise on the target surface.
Other faces use stencil_write_mask_clockwise instead.
The default value is 0xffffffff.
fail_operation_counter_clockwise: StencilOperation
                           Specifies the operation to do when a fragment fails the stencil test.
The stencil test is the test specified by stencil_test_counter_clockwise.
Only relevant for faces that are counter-clockwise on the target surface. Other faces
use stencil_fail_operation_clockwise instead.
The default value is Keep.
pass_depth_fail_operation_counter_clockwise: StencilOperation
                           Specifies the operation to do when a fragment passes the stencil test but fails the depth test.
The stencil test is the test specified by stencil_test_counter_clockwise.
Only relevant for faces that are counter-clockwise on the target surface. Other faces
use stencil_pass_depth_fail_operation_clockwise instead.
The default value is Keep.
depth_pass_operation_counter_clockwise: StencilOperation
                           Specifies the operation to do when a fragment passes both the stencil and depth tests.
The stencil test is the test specified by stencil_test_counter_clockwise.
Only relevant for faces that are counter-clockwise on the target surface. Other faces
use stencil_depth_pass_operation_clockwise instead.
The default value is Keep.
Trait Implementations
impl Debug for Stencil[src]
impl Clone for Stencil[src]
fn clone(&self) -> Stencil
Returns a copy of the value. Read more
fn clone_from(&mut self, source: &Self)1.0.0
Performs copy-assignment from source. Read more